Full Body Arteriovenous Model
The whole body arteriovenous model adopts a humanoid appearance design, including a transparent humanoid shell, a white hemodynamic platform, a high transparency soft silicone vascular model, touch screen fluid parameter setting, integrated design concept, and can be equipped with a multimodal fluid measurement and control system for real-time measurement and control of blood flow dynamics. The anatomical structure and dimensions of the vascular model are derived from real human CTA/MRI data, and are printed from 1:1 3D reconstruction. The vascular model material adopts high transparency soft silicone, with high simulation degree and friction coefficient close to real human blood vessels. The white blood flow platform has a dual pump system with one circulation pump and one heart pulsation pump built-in. The simulated blood flow technology achieves consistency between the phantom and the real human blood flow mode. The built-in fluid touch screen can adjust various fluid parameters such as fluid temperature, pressure, flow rate, heart rate, etc., supporting the entire system to achieve the effect of simulating real human blood flow dynamics. This product strictly complies with domestic standards and FDA related requirements, and can provide professional and detailed literature support and data reports, effectively promoting the transformation of scientific research achievements.
Market price:
Retail price:
Inventory remaining:
Specialty:
Vascular Interventional Model
Full body Interventional Vascular Model
Keywords:
transparency
measurement
vascular
Email: sales@deweimed.com
隐藏域元素占位
Full Body Arteriovenous Model
The whole body arteriovenous model adopts a humanoid appearance design, including a transparent humanoid shell, a white hemodynamic platform, a high transparency soft silicone vascular model, touch screen fluid parameter setting, integrated design concept, and can be equipped with a multimodal fluid measurement and control system for real-time measurement and control of blood flow dynamics. The anatomical structure and dimensions of the vascular model are derived from real human CTA/MRI data, and are printed from 1:1 3D reconstruction. The vascular model material adopts high transparency soft silicone, with high simulation degree and friction coefficient close to real human blood vessels. The white blood flow platform has a dual pump system with one circulation pump and one heart pulsation pump built-in. The simulated blood flow technology achieves consistency between the phantom and the real human blood flow mode. The built-in fluid touch screen can adjust various fluid parameters such as fluid temperature, pressure, flow rate, heart rate, etc., supporting the entire system to achieve the effect of simulating real human blood flow dynamics. This product strictly complies with domestic standards and FDA related requirements, and can provide professional and detailed literature support and data reports, effectively promoting the transformation of scientific research achievements.
Category:
Vascular Interventional Model
Full body Interventional Vascular Model
Keywords:
transparency
measurement
vascular
Technical Highlights
Product Features
Vascular intervention surgery simulation
Cerebral vascular intervention surgery simulation training (arterial aneurysm embolization, stent thrombectomy), Cardiovascular intervention surgery simulation training (coronary stenosis, bifurcation, CTO intervention procedure simulation); Simulation training for peripheral arteriovenous intervention surgery (abdominal vascular aneurysm embolization, lower limb arterial stenosis opening, etc.); Training on cerebral angiography via radial artery, femoral artery, cardiovascular angiography, and peripheral angiography.
Real surgical instrument operation
This product meets the requirements of testing and simulating real surgical instruments such as guide wires, catheters, and stents.
Specific pathological change module
Simulate pathological conditions such as atherosclerosis, arterial stenosis, aneurysm, etc., which can be used for clinical training, disease diagnosis and treatment research.
Intelligent integration, convenient and easy to use
Integrated design, built-in pump body and pipeline, ready to use out of the box, with one click drainage function and convenient storage. Intelligent touch interface, quickly adjust human hemodynamic parameters, intuitive and easy to operate.
Structure
Arteries: intracranial blood vessels (including common carotid artery, external carotid artery, internal carotid artery, middle cerebral artery, anterior cerebral artery, posterior cerebral artery, Willis ring, anterior cerebral artery, posterior cerebral artery, vertebral basilar artery, posterior cerebellar artery), brachiocephalic artery, bilateral subclavian arteries, bilateral radial ulnar artery, coronary artery (including left main trunk, left anterior descending branch, left circumflex branch, right coronary artery, right posterior ventricular branch, posterior descending branch), aortic arch, descending aorta, abdominal aorta, hepatic and renal artery, superior mesenteric artery, iliac artery, femoral artery, deep femoral artery, popliteal artery, anterior tibial artery, posterior tibial artery, fibular artery, foot dorsal artery)
Veins: intracranial veins, brachiocephalic veins, bilateral subclavian veins, bilateral axillary veins, bifurcating radial veins, superior vena cava, inferior vena cava, coronary sinus vein, renal vein, common iliac vein, external iliac vein, femoral vein, deep femoral vein, great saphenous vein, popliteal vein, anterior tibial vein, posterior tibial vein, fibular vein, dorsal pedis vein
Dimension Drawing
Customization
Customizable intracranial structures (aneurysm size and location), coronary structures (stenosis, OCT lesions, etc.), aortic arch lesion structures (commonly classified into 5 types, etc.), hepatic artery lesion structures, etc.
Accessories
Pressure Sensor
Portable Imaging System
Imaging software
Laptop computer
Mock Thrombus
Desktop C-Arm Imaging System Packaging
Parameters
Category | Elite |
Image | ![]() |
Product Code | QSDJM-Elite |
Main Materials | Silicone 20–50A |
Model Dimensions | 5.91× 1.38× 0.98 ft |
Weight | 44.1lb |
Lead Time | 5 weeks |
Test Report
Related News
Related videos
Biomimetic DSA System (C-arm)
Neurointerventional Surgery Simulation System
Full-Body Arteriovenous Intervention Vascular Model – Flagship Edition
Magical Silicone Airbags: Ultra-Elastic and Adaptable, Crafted with 3D Printing for a Life-Saving "Heart Protector" Armor
Request a quote