Coronary Artery Interventional Model Trainer
Coronary Artery Segment Interventional Model consists of a white Hemodynamic Simulation System equipped with a highly transparent soft silicone vascular model. It features a touch-screen fluid parameter control system and an integrated design concept, and can be equipped with a multi-modal fluid monitoring and control system for real-time hemodynamic monitoring. The vascular anatomy and dimensions are based on 1:1 human CTA/MRI data and produced using 3D reconstruction printing.Made of highly transparent soft silicone, the vascular model offers high fidelity and a friction coefficient closely matching that of real human vessels.
The ""Smart Flow"" System incorporates a built-in cardiac pulsatile pump, which simulates blood flow in a manner consistent with that of the human body. The built-in fluid touchscreen allows adjustment of various fluid parameters such as fluid temperature, pressure, flow rate, heart rate,temperature, pressure, flow rate, and heart rate to achieve realistic hemodynamic effects.
This product strictly complies with ASTM F2394 and the Chinese standard YY/T 0807-2010, *“Test Methods for Securement of Balloon-Expandable Vascular Stents Mounted on Delivery Systems.”*Additionally, it provides comprehensive literature and detailed data reports on neurovascular anatomy,effectively facilitating the translation of scientific research into clinical applications.
Market price:
Retail price:
Inventory remaining:
Specialty:
Vascular Interventional Model
Medical Simulation
Coronary Interventional Model
Keywords:
hemodynamic
transparent
anatomy
Email: sales@deweimed.com
隐藏域元素占位
Coronary Artery Interventional Model Trainer
Coronary Artery Segment Interventional Model consists of a white Hemodynamic Simulation System equipped with a highly transparent soft silicone vascular model. It features a touch-screen fluid parameter control system and an integrated design concept, and can be equipped with a multi-modal fluid monitoring and control system for real-time hemodynamic monitoring. The vascular anatomy and dimensions are based on 1:1 human CTA/MRI data and produced using 3D reconstruction printing.Made of highly transparent soft silicone, the vascular model offers high fidelity and a friction coefficient closely matching that of real human vessels.
The ""Smart Flow"" System incorporates a built-in cardiac pulsatile pump, which simulates blood flow in a manner consistent with that of the human body. The built-in fluid touchscreen allows adjustment of various fluid parameters such as fluid temperature, pressure, flow rate, heart rate,temperature, pressure, flow rate, and heart rate to achieve realistic hemodynamic effects.
This product strictly complies with ASTM F2394 and the Chinese standard YY/T 0807-2010, *“Test Methods for Securement of Balloon-Expandable Vascular Stents Mounted on Delivery Systems.”*Additionally, it provides comprehensive literature and detailed data reports on neurovascular anatomy,effectively facilitating the translation of scientific research into clinical applications.
Category:
Vascular Interventional Model
Medical Simulation
Coronary Interventional Model
Keywords:
hemodynamic
transparent
anatomy
Technical Highlights
Product Features
Vascular Intervention Simulation
Supports cardiovascular procedures simulation including retrograde recanalization, coronary stenosis, bifurcation, and CTO interventions.Includes angiography training via radial,femoral and cerebral access.
Real Device Compatibility
Supports simulation and training with standard interventional tools such as J-tip guidewires, hydrophilic-coated guidewires, guide catheters, balloon catheters, drug-eluting stents, and bioresorbable stents.
Diverse Pathology and Material Fidelity
High-transparency silicone vessels with friction properties similar to human arteries. Validated to national and industry standards with full quality traceability. Supports simulation of atherosclerosis, dissection, and aneurysm.
Integrated Smart System
Built-in pump and tubing system, ready to use with one-touch drainage. Touchscreen interface allows quick adjustment of hemodynamic parameters. Embedded Light Panel Provides uniform illumination similar to a ""shadowless lamp"", ensuring clear visibility of guidewires, catheters, and stents.
Structure
Head arm trunk artery, bilateral subclavian arteries, radial artery, coronary artery (including: left main trunk, left circumflex branch, left anterior descending branch, left anterior descending branch, left marginal branch, diagonal branch, left anterior descending branch, left circumflex branch, right main coronary branch, posterior interventricular branch, right main coronary branch), main arterial arch, descending aorta, abdominal aorta, renal artery, iliac artery, femoral artery.
Dimension Drawing
Customization
Customizable aortic arch structure (commonly classified into 5 types, etc.), coronary artery structure V3 (which adds coronary tortuosity while implementing V1 surgery), etc.
Accessories
Portable Imaging System
Pressure Sensor
Flow Sensor
Intelligent teaching pulsatile pump
Circulating pump
Integrated pulsatile pump
Parameters
Category | Space | Shell | Pro |
Image | ![]() | ![]() | |
Model | GMYS-Space | GMYS-Shell | GMYS-Pro |
Model | Silicone 20–50A | Silicone 20–50A | Silicone 20–50A |
Dimensions | 3.1*1.2*0.8ft | 3.1*1.2*0.7ft | 3.1*1.2*0.7ft |
Weight | 17.6lb | 17.6lb | 22lb |
Lead Time | 3 weeks | 4 weeks | 4 weeks |
Test Report
Related News
Related videos
Guide wire
3D-printed peripherals
Pulmonary Artery Model
Radial Artery Puncture Arm Model
Request a quote