Coronary Artery Interventional Model Trainer

Coronary Artery Segment Interventional Model consists of a white Hemodynamic Simulation System equipped with a highly transparent soft silicone vascular model. It features a touch-screen fluid parameter control system and an integrated design concept, and can be equipped with a multi-modal fluid monitoring and control system for real-time hemodynamic monitoring.  The vascular anatomy and dimensions are based on 1:1 human CTA/MRI data and produced using 3D reconstruction printing.Made of highly transparent soft silicone, the vascular model offers high fidelity and a friction coefficient closely matching that of real human vessels.

The ""Smart Flow"" System incorporates a built-in cardiac pulsatile pump, which simulates blood flow in a manner consistent with that of the human body. The built-in fluid touchscreen allows adjustment of various fluid parameters such as fluid temperature, pressure, flow rate, heart rate,temperature, pressure, flow rate, and heart rate to achieve realistic hemodynamic effects.

This product strictly complies with ASTM F2394 and the Chinese standard YY/T 0807-2010,  *“Test Methods for Securement of Balloon-Expandable Vascular Stents Mounted on Delivery Systems.”*Additionally, it provides comprehensive literature and detailed data reports on neurovascular anatomy,effectively facilitating the translation of scientific research into clinical applications.

Market price:

Retail price:

Recently added:

    in total 0 items Total 0

    Quantity
    -
    +

    Inventory remaining:

    Specialty:

    Vascular Interventional Model

    Medical Simulation

    Coronary Interventional Model

    Keywords:

    hemodynamic

    transparent

    anatomy


    隐藏域元素占位

    +
    • 2(1751619787499).jpg
    • Shell(1751619788091).jpg
    • 3(1751619787494).jpg
    • 1(1751619787450).jpg

    Coronary Artery Interventional Model Trainer

    Coronary Artery Segment Interventional Model consists of a white Hemodynamic Simulation System equipped with a highly transparent soft silicone vascular model. It features a touch-screen fluid parameter control system and an integrated design concept, and can be equipped with a multi-modal fluid monitoring and control system for real-time hemodynamic monitoring.  The vascular anatomy and dimensions are based on 1:1 human CTA/MRI data and produced using 3D reconstruction printing.Made of highly transparent soft silicone, the vascular model offers high fidelity and a friction coefficient closely matching that of real human vessels.

    The ""Smart Flow"" System incorporates a built-in cardiac pulsatile pump, which simulates blood flow in a manner consistent with that of the human body. The built-in fluid touchscreen allows adjustment of various fluid parameters such as fluid temperature, pressure, flow rate, heart rate,temperature, pressure, flow rate, and heart rate to achieve realistic hemodynamic effects.

    This product strictly complies with ASTM F2394 and the Chinese standard YY/T 0807-2010,  *“Test Methods for Securement of Balloon-Expandable Vascular Stents Mounted on Delivery Systems.”*Additionally, it provides comprehensive literature and detailed data reports on neurovascular anatomy,effectively facilitating the translation of scientific research into clinical applications.

    Category:

    Vascular Interventional Model

    Medical Simulation

    Coronary Interventional Model

    Keywords:

    hemodynamic

    transparent

    anatomy

    Technical Highlights Structure Parameters Test Report Customer Case Studies Related videos

    Technical Highlights


    Integrated Design
    High transparency
    High-Definition Touch
    One-click illumination

    Product Features


    Vascular Intervention Simulation

    Vascular Intervention Simulation

    Supports cardiovascular procedures simulation including retrograde recanalization, coronary stenosis, bifurcation, and CTO interventions.Includes angiography training via radial,femoral and cerebral access.

    Real Device Compatibility

    Real Device Compatibility

    Supports simulation and training with standard interventional tools such as J-tip guidewires, hydrophilic-coated guidewires, guide catheters, balloon catheters, drug-eluting stents, and bioresorbable stents.

    Diverse Pathology and Material Fidelity

    Diverse Pathology and Material Fidelity

    High-transparency silicone vessels with friction properties similar to human arteries. Validated to national and industry standards with full quality traceability. Supports simulation of atherosclerosis, dissection, and aneurysm.

    Integrated Smart System

    Integrated Smart System

    Built-in pump and tubing system, ready to use with one-touch drainage. Touchscreen interface allows quick adjustment of hemodynamic parameters. Embedded Light Panel Provides uniform illumination similar to a ""shadowless lamp"", ensuring clear visibility of guidewires, catheters, and stents.

    Structure


    Head arm trunk artery, bilateral subclavian arteries, radial artery, coronary artery (including: left main trunk, left circumflex branch, left anterior descending branch, left anterior descending branch, left marginal branch, diagonal branch, left anterior descending branch, left circumflex branch, right main coronary branch, posterior interventricular branch, right main coronary branch), main arterial arch, descending aorta, abdominal aorta, renal artery, iliac artery, femoral artery.    

    Dimension Drawing


    Coronary Intervention Vascular Model – Demonstration Version

    Customization

    Customizable aortic arch structure (commonly classified into 5 types, etc.), coronary artery structure V3 (which adds coronary tortuosity while implementing V1 surgery), etc.

    Accessories


    Portable Imaging System

    Portable Imaging System

    Pressure Sensor

    Pressure Sensor

    Flow Sensor

    Flow Sensor

    Intelligent teaching pulsatile pump

    Intelligent teaching pulsatile pump

    Circulating pump

    Circulating pump

    Integrated pulsatile pump

    Integrated pulsatile pump

    Parameters


    Category
    SpaceShell
    Pro
    Image
    Model
    GMYS-Space
    GMYS-Shell
    GMYS-Pro
    Model
    Silicone 20–50A
    Silicone 20–50A
    Silicone 20–50A
    Dimensions
    3.1*1.2*0.8ft
    3.1*1.2*0.7ft
    3.1*1.2*0.7ft
    Weight
    17.6lb
    17.6lb
    22lb
    Lead Time
    3 weeks
    4 weeks
    4 weeks

    Customer Case Studies


    Related News


    Related videos


    Close

    Guide wire

    Close

    3D-printed peripherals

    Close

    Pulmonary Artery Model

    Close

    Radial Artery Puncture Arm Model


    Request a quote

    *Please keep your phone accessible—we'll reach out to you within 24 hours.

    Submit a message

    Request a quote

    *Please keep your phone accessible—we'll reach out to you within 24 hours.